Gas Boosters to 2,400 bar (36,000psi)

Note : pA = Gas Inlet pressure / pL = Air drive pressure / pB = Gas Outlet pressure
ModelDLE 75-GGDLE 15-75-GGDLE 30-75-GGDLE 75-1-2-GG
Model
Pressure Ratio1:751:15 / 1:751:30 / 1:751:150
Max Compression Ratio1:201:1001:501:20
Stage Ratio-1:51:2.5-
Min Gas Inlet Pressure pA in bar (psi)35 (507)7 (101)15 (217)45(652)
Max Gas Inlet Pressure pA in bar (psi)1,500 (21,750)3.5 x pL20 x pL1,500 (21,750)
Max Permitted Outlet Pressure pB in bar (psi)1,500 (21,750)1,500 (21,750)1,500 (21,750)1,500 (21,750)
Formula To Calculate Gas Outlet Pressure pB75 x pL + pA75 x pL + 5 x pA75 x pL + 2.5 x pA150 x pL
Displacement Volume In cm3 (ins3)50 (3.05)122(7.44)60 (3.66)25 (1.52)
Air Drive pA In bar (psi)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)
Air Consumption In L/min400-1,980 (14.1– 69.9)400-1,980 (14.1– 69.9)400-1,980 (14.1– 69.9)600-2,400 (21.2-84.8)
Gas Inlet Connection1/4 BSP1/2 BSP1/4 BSP1/4 BSP
Gas Outlet Connection1/4 BSP1/4 BSP1/4 BSP1/4 BSP
Air Drive Connection3/4 BSP3/4 BSP3/4 BSP3/4 BSP
Net Weight (kg)18191920
ModelDLE 75-2-GGDLE 15-75-2-GGDLE 30-75-2-GG
Model
Pressure Ratio1:1501:30 / 1:1501:60 / 1:150
Max Compression Ratio1:201:1001:50
Stage Ratio-1:51:2.5
Min Gas Inlet Pressure pA in bar (psi)45 (652)7 (101)15 (217)
Max Gas Inlet Pressure pA in bar (psi)1,500 (21,750)7 x pL40 x pL
Max Permitted Outlet Pressure pB in bar (psi)1,500 (21,750)1,500 (21,750)1,500 (21,750)
Formula To Calculate Gas Outlet Pressure pB150 X pL + pA150 X pL + 5 x pA150 X pL + 2.5 x pA
Displacement Volume In cm3 (ins3)50 (3.05)122 (7.44)60 (3.66)
Air Drive pA In bar (psi)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)
Air Consumption In L/min600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)
Gas Inlet Connection1/4 BSP1/2 BSP1/4 BSP
Gas Outlet Connection1/4 BSP1/4 BSP1/4 BSP
Air Drive Connection3/4 BSP3/4 BSP3/4 BSP
Net Weight (kg)232424
ModelDLE 30-75-2-25-GGDLE 30-75-2-30-GGDLE 30-75-3-36-GG
Model
Pressure Ratio1:60 / 1:1501:60 / 1:1501:60 / 1:150
Max Compression Ratio1:501:501:50
Stage Ratio1:2.5.1:2.5.1:2.5.
Min Gas Inlet Pressure pA in bar (psi)15 (217)15 (217)15 (217)
Max Gas Inlet Pressure pA in bar (psi)40 x pL40 x pL40 x pL
Max Permitted Outlet Pressure pB in bar (psi)1,800 (25,000)2,100 (30,000)2,400 (36,000)
Formula To Calculate Gas Outlet Pressure pB150 X pL + 2.5 x pA150 X pL + 2.5 x pA150 X pL + 2.5 x pA
Displacement Volume In cm3 (ins3)60 (3.66)60 (3.66)60 (3.66)
Air Drive pA In bar (psi)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)
Air Consumption In L/min600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)
Gas Inlet Connection1/4 BSP1/4 BSP1/4 BSP
Gas Outlet Connection1/4 BSP1/4 BSP1/4 BSP
Air Drive Connection3/4 BSP3/4 BSP3/4 BSP
Net Weight (kg)242424
Enquiries

If you would like to enquire about any of our products, please click on the button below, or get in contact with our office

Tel 01606 636000 or email sales@maximator.co.uk